{"product_id":"ecnr100","title":"ECNR100 - 100 Amp Fuse","description":"\u003cp\u003e\u003cstrong\u003eECNR100 - 100 Amp Fuse\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen electrical systems are exposed to demanding operating conditions, dependable overcurrent protection becomes critical. The Eaton Edison ECNR100 is a 100 Amp Class RK5 dual-element fuse built to help protect valuable equipment from overloads and short circuits while allowing the temporary current surges commonly associated with motor startups and other inductive loads. It's the type of fuse often found in commercial and industrial facilities where keeping equipment running safely is just as important as protecting it when faults occur.\u003c\/p\u003e\n\u003cp\u003eWhether you're maintaining a motor control center, servicing distribution equipment, or replacing an existing Class RK5 fuse, the ECNR100 provides the protection characteristics electrical professionals expect. Its dual-element design allows it to tolerate brief startup currents that are a normal part of many electrical systems. Instead of opening during every momentary surge, it remains focused on responding when a genuine overload or fault develops.\u003c\/p\u003e\n\u003cp\u003eFor maintenance teams, electricians, and facility managers looking to replace an existing RK5 fuse or maintain equipment built around this protection class, the Eaton Edison ECNR100 continues to be a practical and dependable choice for everyday electrical applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features and Benefits\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e100 Amp current rating for industrial and commercial electrical applications\u003c\/li\u003e\n\u003cli\u003eClass RK5 fuse classification for compatibility with RK5 fuse systems\u003c\/li\u003e\n\u003cli\u003eDual-element design helps accommodate temporary motor startup and inrush currents\u003c\/li\u003e\n\u003cli\u003eProtects equipment from overloads and short-circuit conditions\u003c\/li\u003e\n\u003cli\u003e200 kAIC interrupting rating for high fault-current protection\u003c\/li\u003e\n\u003cli\u003eRated for 250 VAC and 125 VDC circuits\u003c\/li\u003e\n\u003cli\u003eNon-indicating fuse construction\u003c\/li\u003e\n\u003cli\u003eNon-current-limiting design for applications requiring this protection characteristic\u003c\/li\u003e\n\u003cli\u003eSuitable for motor circuits, control panels, machinery, and distribution equipment\u003c\/li\u003e\n\u003cli\u003eCE Marked for recognized compliance requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Eaton\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e Edison ECNR\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCatalog Number:\u003c\/strong\u003e ECNR100\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Fuse\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClass:\u003c\/strong\u003e RK5\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmperage Rating:\u003c\/strong\u003e 100 A\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Rating:\u003c\/strong\u003e 250 VAC, 125 VDC\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterrupt Rating:\u003c\/strong\u003e 200 kAIC\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time:\u003c\/strong\u003e 10 Seconds at 500%\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Elements:\u003c\/strong\u003e Dual\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuse Indicator:\u003c\/strong\u003e Non-Indicating\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpecial Features:\u003c\/strong\u003e Non Current Limiting\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLength:\u003c\/strong\u003e 7.13 in\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 1.56 in\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 1.56 in\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.85 lb\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUPC:\u003c\/strong\u003e 782634507437\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMaterial Compliance and Certifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe ECNR100 is CE Marked and manufactured to Eaton specifications for use in electrical systems requiring Class RK5 overcurrent protection. It is intended for installation in properly rated equipment and should be installed and serviced by qualified personnel in accordance with applicable electrical codes and safety practices.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhere It Works Best\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMotor branch circuits\u003c\/li\u003e\n\u003cli\u003eIndustrial control panels\u003c\/li\u003e\n\u003cli\u003eManufacturing and processing equipment\u003c\/li\u003e\n\u003cli\u003eHVAC systems\u003c\/li\u003e\n\u003cli\u003eMotor control centers\u003c\/li\u003e\n\u003cli\u003eCommercial electrical distribution systems\u003c\/li\u003e\n\u003cli\u003eMachinery and automation equipment\u003c\/li\u003e\n\u003cli\u003eMaintenance and replacement projects\u003c\/li\u003e\n\u003cli\u003eFacilities with temporary startup or inrush current conditions\u003c\/li\u003e\n\u003cli\u003eApplications requiring Class RK5 fuse protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\n\u003cbr\u003e\n\u003cdiv\u003e\n\u003cblockquote\u003e\n\u003cp style=\"font-size: 12px;\"\u003e\u003cem\u003eUse of Original Equipment Manufacturer (OEM) trademarks, names, and logos is for informational and identification purposes only. This does not imply any affiliation, sponsorship, endorsement, or approval by the original equipment manufacturer.\u003cstrong\u003e CIRCUIT BREAKER SUPERSTORE®\u003c\/strong\u003e is an independent reseller and is \u003cstrong\u003enot \u003c\/strong\u003ean authorized distributor, affiliate, or representative of any manufacturer. Manufacturer warranties do \u003cstrong\u003enot\u003c\/strong\u003e apply unless expressly stated. All trademarks and registered trademarks are the property of their respective owners.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 12px;\"\u003e\u003cem\u003eEaton®, Cutler-Hammer®, Westinghouse®, Challenger®, Bussmann®, Crouse-Hinds®, and Cooper® are registered trademarks of Eaton Corporation plc. Products sold are surplus, used, or refurbished and are \u003cstrong\u003eNOT \u003c\/strong\u003esupplied by Eaton Corporation plc or its affiliates.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Mersen","offers":[{"title":"New In Box","offer_id":50459168047403,"sku":"ECNR100","price":0.0,"currency_code":"USD","in_stock":false},{"title":"Refurbished","offer_id":50459168080171,"sku":"ECNR100  [R]","price":0.0,"currency_code":"USD","in_stock":false}],"url":"https:\/\/store.circuitbreakersuperstore.com\/products\/ecnr100","provider":"CIRCUIT BREAKER SUPERSTORE®","version":"1.0","type":"link"}