{"product_id":"ecnr1","title":"ECNR1 - 1 Amp Fuse","description":"\u003cp\u003e\u003cstrong\u003eECNR1 - 1 Amp Fuse\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Eaton Edison ECNR1 is a 1 Amp Class RK5 dual-element fuse used to protect low-amperage circuits in commercial and industrial electrical systems. You'll often find this type of fuse in control panels, motor circuits, machinery, and other equipment where dependable overcurrent protection is important but occasional startup surges are part of normal operation.\u003c\/p\u003e\n\u003cp\u003eThe ECNR1 carries a 200 kA interrupting rating, making it suitable for applications where higher available fault currents may be present. When a short circuit occurs, the fuse is designed to clear the fault safely before damage can spread to connected equipment.\u003c\/p\u003e\n\u003cp\u003eWith a response time of approximately 8 seconds at 500% of rated current, the ECNR1 provides the time-delay characteristics often needed in circuits that experience brief current surges during startup.\u003c\/p\u003e\n\u003cp\u003eWhether you're maintaining production equipment, servicing a control cabinet, or replacing a failed fuse during routine maintenance, the Eaton Edison ECNR1 provides the same ratings and performance characteristics that many facilities rely on to keep electrical systems operating safely.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features and Benefits\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1 Amp Class RK5 fuse for low-amperage circuit protection\u003c\/li\u003e\n\u003cli\u003eDual-element construction helps accommodate temporary inrush currents\u003c\/li\u003e\n\u003cli\u003eProvides overload and short-circuit protection\u003c\/li\u003e\n\u003cli\u003e200 kA interrupting rating for applications with high available fault current\u003c\/li\u003e\n\u003cli\u003eRated for both 250 VAC and 125 VDC electrical systems\u003c\/li\u003e\n\u003cli\u003eNon-indicating design for straightforward installation and replacement\u003c\/li\u003e\n\u003cli\u003eSuitable for industrial control panels, machinery, and distribution equipment\u003c\/li\u003e\n\u003cli\u003eCompatible with systems designed for Class RK5 fuse protection\u003c\/li\u003e\n\u003cli\u003eHelps protect sensitive electrical components from overcurrent conditions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCatalog Number:\u003c\/strong\u003e ECNR1\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Eaton\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e Edison\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Fuse\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClass:\u003c\/strong\u003e RK5\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmperage Rating:\u003c\/strong\u003e 1 Amp\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Rating:\u003c\/strong\u003e 250 VAC, 125 VDC\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterrupt Rating:\u003c\/strong\u003e 200 kAIC\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time:\u003c\/strong\u003e 8 seconds at 500% rated current\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Elements:\u003c\/strong\u003e Dual Element\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuse Indicator:\u003c\/strong\u003e Non-Indicating\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Limiting:\u003c\/strong\u003e Non Current Limiting\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging Type:\u003c\/strong\u003e Standard\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLength:\u003c\/strong\u003e 2 in\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 0.565 in\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 0.565 in\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.5 lb\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMaterial Compliance and Certifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe ECNR1 is CE Marked and manufactured to meet applicable industry requirements for overcurrent protection devices. It is intended for use in properly rated electrical systems and should be installed and serviced by qualified personnel in accordance with applicable electrical codes, equipment specifications, and safety practices.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhere It Works Best\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial control panels\u003c\/li\u003e\n\u003cli\u003eMotor branch circuits\u003c\/li\u003e\n\u003cli\u003eManufacturing and processing equipment\u003c\/li\u003e\n\u003cli\u003eElectrical distribution systems\u003c\/li\u003e\n\u003cli\u003eEquipment requiring Class RK5 fuse protection\u003c\/li\u003e\n\u003cli\u003eCommercial electrical installations\u003c\/li\u003e\n\u003cli\u003eMaintenance and replacement projects\u003c\/li\u003e\n\u003cli\u003eCircuits with temporary inrush current conditions\u003c\/li\u003e\n\u003cli\u003eLow-amperage protection applications\u003c\/li\u003e\n\u003cli\u003eControl and automation systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\n\u003cbr\u003e\n\u003cdiv\u003e\n\u003cblockquote\u003e\n\u003cp style=\"font-size: 12px;\"\u003e\u003cem\u003eUse of Original Equipment Manufacturer (OEM) trademarks, names, and logos is for informational and identification purposes only. This does not imply any affiliation, sponsorship, endorsement, or approval by the original equipment manufacturer.\u003cstrong\u003e CIRCUIT BREAKER SUPERSTORE®\u003c\/strong\u003e is an independent reseller and is \u003cstrong\u003enot \u003c\/strong\u003ean authorized distributor, affiliate, or representative of any manufacturer. Manufacturer warranties do \u003cstrong\u003enot\u003c\/strong\u003e apply unless expressly stated. All trademarks and registered trademarks are the property of their respective owners.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 12px;\"\u003e\u003cem\u003eEaton®, Cutler-Hammer®, Westinghouse®, Challenger®, Bussmann®, Crouse-Hinds®, and Cooper® are registered trademarks of Eaton Corporation plc. Products sold are surplus, used, or refurbished and are \u003cstrong\u003eNOT \u003c\/strong\u003esupplied by Eaton Corporation plc or its affiliates.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Mersen","offers":[{"title":"New In Box","offer_id":50459167916331,"sku":"ECNR1","price":0.0,"currency_code":"USD","in_stock":false},{"title":"Refurbished","offer_id":50459167949099,"sku":"ECNR1  [R]","price":0.0,"currency_code":"USD","in_stock":false}],"url":"https:\/\/store.circuitbreakersuperstore.com\/products\/ecnr1","provider":"CIRCUIT BREAKER SUPERSTORE®","version":"1.0","type":"link"}