{"product_id":"cfd63b100","title":"CFD63B100 - 100A Circuit Breaker","description":"\u003cp\u003e\u003cstrong\u003eCFD63B100 - 100A Circuit Breaker\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen a facility depends on consistent power distribution, having the right circuit protection in place matters. The CFD63B100 100 Amp 3-Pole Molded Case Circuit Breaker is designed for commercial and industrial electrical systems that require a compatible Sentron CFD6 frame breaker with a 100-amp rating and high interrupting capacity.\u003c\/p\u003e\n\u003cp\u003eThis breaker combines a 3-pole configuration, fuseless current-limiting design, and a non-interchangeable trip unit in a compact package built for demanding electrical environments. With interrupting ratings of 200kA at 240VAC and 480VAC, along with 100kA at 600VAC, the CFD63B100 is suited for applications where substantial fault-current protection is required.\u003c\/p\u003e\n\u003cp\u003eWhether you're maintaining an existing electrical distribution system, replacing a failed breaker, or supporting ongoing facility operations, finding a breaker that matches the original equipment specifications can help minimize complications during installation. The CFD63B100 is commonly used in switchboards, panelboards, motor control equipment, and HVAC systems where a compatible CFD6-frame breaker is required. Because it includes load-side terminals and is designed for 50\/60Hz operation in environments up to 40°C (104°F), it fits the needs of many established commercial and industrial installations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features and Benefits\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e100 amp current rating for commercial and industrial applications\u003c\/li\u003e\n\u003cli\u003e3-pole design for three-phase electrical systems\u003c\/li\u003e\n\u003cli\u003eSentron CFD6 frame construction\u003c\/li\u003e\n\u003cli\u003eFuseless current-limiting technology helps reduce the effects of high fault currents\u003c\/li\u003e\n\u003cli\u003eNon-interchangeable trip unit configuration\u003c\/li\u003e\n\u003cli\u003eHACR rated for HVAC-related applications\u003c\/li\u003e\n\u003cli\u003eIncludes load-side terminals\u003c\/li\u003e\n\u003cli\u003eDesigned for operation at 50\/60Hz\u003c\/li\u003e\n\u003cli\u003eSuitable for ambient temperatures up to 40°C (104°F)\u003c\/li\u003e\n\u003cli\u003eBuilt to last in demanding electrical environments\u003c\/li\u003e\n\u003cli\u003eMaintains form-fit-function compatibility with applicable equipment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e CFD63B100\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e CFD6\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCircuit Breaker Type:\u003c\/strong\u003e Molded Case Circuit Breaker\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles:\u003c\/strong\u003e 3\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmperage:\u003c\/strong\u003e 100A\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 50\/60Hz\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient Rating:\u003c\/strong\u003e 40°C\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrame:\u003c\/strong\u003e Sentron\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrip Unit:\u003c\/strong\u003e Non-Interchangeable\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Limiting:\u003c\/strong\u003e Fuseless Current Limiting\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterrupting Capacity (A.I.C.)\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e200kA @ 240VAC\u003c\/li\u003e\n\u003cli\u003e200kA @ 480VAC\u003c\/li\u003e\n\u003cli\u003e100kA @ 600VAC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApproximate Dimensions:\u003c\/strong\u003e 4.50\"W x 14.25\"H x 4.00\"D\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 4.50\"\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 14.25\"\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 4.00\"\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApproximate Shipping Weight:\u003c\/strong\u003e 39 lbs\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad-Side Terminals\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMaterial Compliance and Certifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHACR Rated\u003c\/li\u003e\n\u003cli\u003eDesigned for 50\/60Hz operation\u003c\/li\u003e\n\u003cli\u003eRated for use in 40°C ambient environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWhere It Works Best\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eThe CFD63B100 is frequently found in commercial buildings, manufacturing facilities, industrial plants, motor control centers, switchboards, panelboards, and HVAC systems. It is especially useful for maintenance and replacement projects where preserving the original system design and equipment compatibility is important.\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cbr\u003e\n\u003cdiv\u003e\n\u003cblockquote\u003e\n\u003cp style=\"font-size: 12px;\"\u003e\u003cem\u003eUse of Original Equipment Manufacturer (OEM) trademarks, names, and logos is for informational and identification purposes only. This does not imply any affiliation, sponsorship, endorsement, or approval by the original equipment manufacturer.\u003cstrong\u003e CIRCUIT BREAKER SUPERSTORE®\u003c\/strong\u003e is an independent reseller and is \u003cstrong\u003enot \u003c\/strong\u003ean authorized distributor, affiliate, or representative of any manufacturer. Manufacturer warranties do \u003cstrong\u003enot\u003c\/strong\u003e apply unless expressly stated. All trademarks and registered trademarks are the property of their respective owners.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 12px;\"\u003e\u003cem\u003eSiemens®, I-T-E®, and Murray® are registered trademarks of Siemens AG. Products sold are surplus, used, or refurbished and are \u003cstrong\u003eNOT \u003c\/strong\u003esupplied by Siemens AG or its affiliates.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"SIEMENS","offers":[{"title":"New In Box","offer_id":49504054903083,"sku":"CFD63B100","price":0.0,"currency_code":"USD","in_stock":true},{"title":"Refurbished","offer_id":49504054935851,"sku":"CFD63B100 [R]","price":0.0,"currency_code":"USD","in_stock":false}],"url":"https:\/\/store.circuitbreakersuperstore.com\/products\/cfd63b100","provider":"CIRCUIT BREAKER SUPERSTORE®","version":"1.0","type":"link"}