{"product_id":"3va5225-7ec31-0aa0","title":"3VA5225-7EC31-0AA0 - CFAS 250 Amp Circuit Breaker","description":"\u003cp\u003e\u003cstrong\u003e3VA5225-7EC31-0AA0 - CFAS 250 Amp Circuit Breaker\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen you’re dealing with serious electrical loads, you don’t want to second-guess your protection. The Siemens 3VA5225-7EC31-0AA0 circuit breaker is designed for exactly that kind of environment—where reliability isn’t negotiable, and downtime costs real money. This 250-amp, 3-pole breaker is part of the well-known 3VA52 series and is built to handle demanding commercial and industrial applications. What really sets it apart is its 100kA interrupting capacity at 480V, giving you the confidence to handle high-fault conditions without hesitation. It uses a thermal magnetic trip unit (TM230) with fixed settings, which means fewer variables and less room for error. The overload protection is set at 250A, and the instantaneous trip kicks in at 10 times the rated current. In plain terms, it reacts fast when something goes wrong, without needing constant adjustment or fine-tuning. If you’re replacing an existing breaker or building out a new system, this is the kind of component you install once—and trust to do its job.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features and Benefits\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Interrupting Capacity:\u003c\/strong\u003e 100kA @ 480V helps protect against severe fault conditions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Magnetic Trip Unit:\u003c\/strong\u003e Combines overload and short-circuit protection in one simple design\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFixed Protection Settings:\u003c\/strong\u003e No adjustments needed, reducing setup time and potential errors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e250 Amp Rating:\u003c\/strong\u003e Well-suited for demanding electrical loads\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3-Pole Configuration:\u003c\/strong\u003e Standard for three-phase systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact Size:\u003c\/strong\u003e Easier to integrate into panels and switchgear\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConsistent Performance:\u003c\/strong\u003e Built for long-term, dependable operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e 3VA5225-7EC31-0AA0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e 3VA52 (UL Frame 250)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles:\u003c\/strong\u003e 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmperage:\u003c\/strong\u003e 250A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterrupting Rating:\u003c\/strong\u003e 100kA @ 480V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrip Unit:\u003c\/strong\u003e Thermal Magnetic (TM230)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverload Protection (Ir):\u003c\/strong\u003e 250A (fixed)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort-Circuit Protection (Ii):\u003c\/strong\u003e 10x In (fixed)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterrupting Class:\u003c\/strong\u003e C (CFAS)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 9.65\" H x 6.3\" W x 5.9\" D\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMaterial Compliance and Certifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eManufactured to meet UL standards for molded case circuit breakers\u003c\/li\u003e\n\u003cli\u003eDesigned for use in low-voltage power distribution systems\u003c\/li\u003e\n\u003cli\u003eAligns with current electrical safety and compliance expectations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWhere It Works Best\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eYou’ll typically find this breaker in places where performance and reliability matter day in and day out:\u003c\/li\u003e\n\u003cli\u003eCommercial buildings and large facilities\u003c\/li\u003e\n\u003cli\u003eIndustrial plants and production environments\u003c\/li\u003e\n\u003cli\u003eElectrical distribution panels and switchgear\u003c\/li\u003e\n\u003cli\u003eData centers and backup power systems\u003c\/li\u003e\n\u003cli\u003eProtection for feeders, motors, and heavy equipment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\n\u003cbr\u003e\n\u003cdiv\u003e\n\u003cblockquote\u003e\n\u003cp style=\"font-size: 12px;\"\u003e\u003cem\u003eUse of Original Equipment Manufacturer (OEM) trademarks, names, and logos is for informational and identification purposes only. This does not imply any affiliation, sponsorship, endorsement, or approval by the original equipment manufacturer.\u003cstrong\u003e CIRCUIT BREAKER SUPERSTORE®\u003c\/strong\u003e is an independent reseller and is \u003cstrong\u003enot \u003c\/strong\u003ean authorized distributor, affiliate, or representative of any manufacturer. Manufacturer warranties do \u003cstrong\u003enot\u003c\/strong\u003e apply unless expressly stated. All trademarks and registered trademarks are the property of their respective owners.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 12px;\"\u003e\u003cem\u003eSiemens®, I-T-E®, and Murray® are registered trademarks of Siemens AG. Products sold are surplus, used, or refurbished and are \u003cstrong\u003eNOT \u003c\/strong\u003esupplied by Siemens AG or its affiliates.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"SIEMENS","offers":[{"title":"New","offer_id":51696282403115,"sku":"3VA5225-7EC31-0AA0","price":1500.0,"currency_code":"USD","in_stock":false}],"url":"https:\/\/store.circuitbreakersuperstore.com\/products\/3va5225-7ec31-0aa0","provider":"CIRCUIT BREAKER SUPERSTORE®","version":"1.0","type":"link"}