{"product_id":"3va5222-6ed31-0aa0","title":"3VA5222-6ED31-0AA0 - HFAS 225 Amp Circuit Breaker","description":"\u003cp\u003e\u003cstrong\u003e3VA5222-6ED31-0AA0 - HFAS 225 Amp Circuit Breaker\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIf you’re replacing a 225A 3-pole breaker or setting up a new panel, the Siemens 3VA5222-6ED31-0AA0 is one of those parts that just makes sense. It’s built for standard three-phase systems and handles both overloads and short circuits without needing any extra setup or adjustments. This breaker uses a thermal magnetic trip unit, so it works the way most electricians expect. It’ll carry your load at 225 amps, trip on overload when it needs to, and react instantly if there’s a short circuit. The instantaneous trip is set at 10 times the rated current, which is typical for protecting equipment without nuisance tripping. With a 35kA interrupting rating at 480V, it’s suitable for a wide range of commercial and light industrial applications. Whether it’s going into a distribution panel, feeding HVAC equipment, or replacing an existing Siemens unit, it’s a straightforward fit. It’s also part of the 3VA5 series, so the footprint is compact and modern—helpful if you’re working in a tight panel or upgrading older gear.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features and Benefits\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e225 Amp circuit breaker for reliable load handling\u003c\/li\u003e\n\u003cli\u003e3-pole design for three-phase electrical systems\u003c\/li\u003e\n\u003cli\u003eThermal magnetic trip unit (TM210) – simple, proven protection\u003c\/li\u003e\n\u003cli\u003e35kA AIC rating at 480V for higher fault current capacity\u003c\/li\u003e\n\u003cli\u003eFixed overload protection (Ir = 225A) – no field adjustments needed\u003c\/li\u003e\n\u003cli\u003eInstantaneous trip at 10x In for fast short-circuit response\u003c\/li\u003e\n\u003cli\u003eCompact 3VA52 frame – easier to fit in existing panels\u003c\/li\u003e\n\u003cli\u003eGood choice for replacement or new installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Siemens\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e 3VA5222-6ED31-0AA0\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrame Type:\u003c\/strong\u003e 3VA52\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles:\u003c\/strong\u003e 3\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmperage:\u003c\/strong\u003e 225A\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Rating:\u003c\/strong\u003e Up to 480V\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterrupting Capacity:\u003c\/strong\u003e 35kA @ 480V\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrip Unit:\u003c\/strong\u003e Thermal Magnetic (TM210, FTFM)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverload Protection (Ir):\u003c\/strong\u003e 225A (fixed)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort-Circuit Protection (Ii):\u003c\/strong\u003e 10 × In\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 9.65\" H × 6.3\" W × 5.9\" D\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMaterial Compliance and Certifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL Listed for use in North American electrical systems\u003c\/li\u003e\n\u003cli\u003eBuilt to meet standard commercial and industrial safety requirements\u003c\/li\u003e\n\u003cli\u003eDesigned for safe interruption of fault currents in typical applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWhere It Works Best\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThis breaker is commonly used in:\u003c\/li\u003e\n\u003cli\u003eCommercial electrical panels\u003c\/li\u003e\n\u003cli\u003eIndustrial equipment and machinery\u003c\/li\u003e\n\u003cli\u003eHVAC systems and motor loads\u003c\/li\u003e\n\u003cli\u003eDistribution boards and switchgear\u003c\/li\u003e\n\u003cli\u003eDirect replacements for existing 225A Siemens breakers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\n\u003cbr\u003e\n\u003cdiv\u003e\n\u003cblockquote\u003e\n\u003cp style=\"font-size: 12px;\"\u003e\u003cem\u003eUse of Original Equipment Manufacturer (OEM) trademarks, names, and logos is for informational and identification purposes only. This does not imply any affiliation, sponsorship, endorsement, or approval by the original equipment manufacturer.\u003cstrong\u003e CIRCUIT BREAKER SUPERSTORE®\u003c\/strong\u003e is an independent reseller and is \u003cstrong\u003enot \u003c\/strong\u003ean authorized distributor, affiliate, or representative of any manufacturer. Manufacturer warranties do \u003cstrong\u003enot\u003c\/strong\u003e apply unless expressly stated. All trademarks and registered trademarks are the property of their respective owners.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 12px;\"\u003e\u003cem\u003eSiemens®, I-T-E®, and Murray® are registered trademarks of Siemens AG. Products sold are surplus, used, or refurbished and are \u003cstrong\u003eNOT \u003c\/strong\u003esupplied by Siemens AG or its affiliates.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"SIEMENS","offers":[{"title":"New","offer_id":51696279257387,"sku":"3VA5222-6ED31-0AA0","price":1500.0,"currency_code":"USD","in_stock":false}],"url":"https:\/\/store.circuitbreakersuperstore.com\/products\/3va5222-6ed31-0aa0","provider":"CIRCUIT BREAKER SUPERSTORE®","version":"1.0","type":"link"}