{"product_id":"3va5217-7ed31-0aa0","title":"3VA5217-7ED31-0AA0 - CFAS 175 Amp Circuit Breaker","description":"\u003cp\u003e\u003cstrong\u003e3VA5217-7ED31-0AA0 - CFAS 175 Amp Circuit Breaker\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Siemens 3VA5217-7ED31-0AA0 is the kind of breaker you install and don’t have to think about again. It’s rated at 175 amps and built to handle serious fault conditions, with a 100kA interrupting rating at 480V—so when something goes wrong, it reacts fast and does what it’s supposed to do. This model uses a thermal magnetic trip unit, which is still the go-to choice for a lot of contractors and facility guys because it’s predictable and proven. Overload protection is fixed at 175A, and the instantaneous trip is set at 10 times that. No tweaking, no guesswork—just install it and move on. It’s part of Siemens’ 3VA5 line, and if you’ve worked with these before, you already know the deal: solid build, consistent performance, and no unnecessary complications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features and Benefits\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh interrupting capacity (100kA @ 480V):\u003c\/strong\u003e for applications where fault current is a real concern\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e175 amp rating:\u003c\/strong\u003e covers a wide range of commercial and industrial loads\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal magnetic trip unit:\u003c\/strong\u003e keeps protection simple and reliable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3-pole configuration:\u003c\/strong\u003e for standard three-phase systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFixed settings:\u003c\/strong\u003e mean faster installs and fewer mistakes in the field\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact footprint:\u003c\/strong\u003e for easier panel integration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt to handle demanding conditions:\u003c\/strong\u003e without overengineering\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Siemens\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e 3VA5217-7ED31-0AA0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e 3VA52\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles:\u003c\/strong\u003e 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmperage:\u003c\/strong\u003e 175A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterrupting Rating:\u003c\/strong\u003e 100kA @ 480V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrip Type:\u003c\/strong\u003e Thermal Magnetic (TM210)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverload Protection (Ir):\u003c\/strong\u003e Fixed at 175A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstantaneous Trip (Ii):\u003c\/strong\u003e 10 × In\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrame Size:\u003c\/strong\u003e 250\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e9.65\" H\u003c\/li\u003e\n\u003cli\u003e6.3\" W\u003c\/li\u003e\n\u003cli\u003e5.9\" D\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMaterial Compliance and Certifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL listed under the Siemens 3VA5 series\u003c\/li\u003e\n\u003cli\u003eMeets standard U.S. electrical compliance requirements\u003c\/li\u003e\n\u003cli\u003eDesigned for use in commercial and industrial power systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWhere It Works Best\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eYou’ll typically see this breaker in:\u003c\/li\u003e\n\u003cli\u003eCommercial buildings and tenant panels\u003c\/li\u003e\n\u003cli\u003eIndustrial equipment and machinery protection\u003c\/li\u003e\n\u003cli\u003eFacilities with a higher available fault current\u003c\/li\u003e\n\u003cli\u003eHVAC systems and motor loads\u003c\/li\u003e\n\u003cli\u003eGeneral three-phase distribution setups\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\n\u003cbr\u003e\n\u003cdiv\u003e\n\u003cblockquote\u003e\n\u003cp style=\"font-size: 12px;\"\u003e\u003cem\u003eUse of Original Equipment Manufacturer (OEM) trademarks, names, and logos is for informational and identification purposes only. This does not imply any affiliation, sponsorship, endorsement, or approval by the original equipment manufacturer.\u003cstrong\u003e CIRCUIT BREAKER SUPERSTORE®\u003c\/strong\u003e is an independent reseller and is \u003cstrong\u003enot \u003c\/strong\u003ean authorized distributor, affiliate, or representative of any manufacturer. Manufacturer warranties do \u003cstrong\u003enot\u003c\/strong\u003e apply unless expressly stated. All trademarks and registered trademarks are the property of their respective owners.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 12px;\"\u003e\u003cem\u003eSiemens®, I-T-E®, and Murray® are registered trademarks of Siemens AG. Products sold are surplus, used, or refurbished and are \u003cstrong\u003eNOT \u003c\/strong\u003esupplied by Siemens AG or its affiliates.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"SIEMENS","offers":[{"title":"New","offer_id":51696280043819,"sku":"3VA5217-7ED31-0AA0","price":1500.0,"currency_code":"USD","in_stock":false}],"url":"https:\/\/store.circuitbreakersuperstore.com\/products\/3va5217-7ed31-0aa0","provider":"CIRCUIT BREAKER SUPERSTORE®","version":"1.0","type":"link"}